Part Number Description Comments
No result
Gas Supply
004-62230-32 Gas Pressure Regulator for CO2 2 stage gas regulator, CGA 320, delivery pressure range: 2-30 psig 
004-62230-35 Gas Pressure Regulator for CO and H2 2 stage gas regulator, CGA 350, delivery pressure range: 2-30 psig 
004-62230-54 Gas Pressure Regulator for O2 2 stage gas regulator, CGA 540, delivery pressure range: 2-30 psig 
004-62230-58 Gas Pressure Regulator He, N2, Kr, Ar 2 stage gas regulator, CGA 580, delivery pressure range: 2-30 psig 
004-62230-326 Gas Pressure Regulator for N2O 2 stage gas regulator, CGA 326, delivery pressure range: 2-30 psig 
004-62230-705 Gas Pressure Regulator for NH3 2 stage gas regulator, CGA 705, delivery pressure range: 2-30 psig 
004-25549-00 Reducer 1/8 in. Tube x 1/4 in. Tube
004-25103-00 Ferrule, Front, Teflon, 1/4 in. For use with 1/8 in. tube × 1/4 in. tube reducer
004-25104-00 Ferrule, Rear, Nylon, 1/4 in. For use with 1/8 in. tube × 1/4 in. tube reducer
004-33601-00 Gas Regulator Expansion Kit Adds an additional outlet to the gas regulator
004-33602-00 Gas Regulator Pressure Relief Kit Prevents excessive gas pressure in the event of a regulator failure (not to be used with toxic gases)
290-25846-00 Gas Inlet Line 6' For connecting gas to the instrument, Copper, 1/8 in x 6 ft long
290-25846-01 Gas Inlet Line 16' For connecting gas to the instrument, Copper, 1/8 in x 16 ft long
201-25818-00 Gas Inlet Line 6', SS For connecting gas to the instrument, Stainless Steel, 1/8 in x 6 ft long
201-25818-01 Gas Inlet Line 16', SS For connecting gas to the instrument, Stainless Steel, 1/8 in x 16 ft long
004-25913-00 1/8 Peek Ferrule Set  For sealing gas inlet lines into the gas inlet manifold assemblies
Vacuum Supply
062-00200-00 Dry Vacuum Forepump  For systems with high-vacuum option, 115/230 VAC
004-62023-01 Service Kit Vacuum Forepump
062-62801-23 Vacuum Oil Pump, 220/240 V  Replacement pump only, does not include exhaust filter, foreline trap, or vacuum pump tray
062-62801-11 Vacuum Oil Pump, 110/120 V  Replacement pump only, does not include exhaust filter, foreline trap, or vacuum pump tray
062-33002-00 Vacuum Foreline Oil Trap For one vacuum pump, includes: activated alumina, clamps, o-rings, fittings, and housing
004-25509-00  Clamp  NW 10/16, clamp to connect flex tube to pump or instrument
004-25630-00 Centering Ring NW 16, sealing ring to connect forepump to instrument
004-25652-00 O-Ring for Oil Vapor Trap Size 217, Viton
004-16830-00 Activated Alumina 500 g, for oil vapor trap
004-16003-01 Vacuum Pump Oil 1 ltr
004-32177-00 Funnel for Filling Vacuum Pump with Oil
004-27040-00 Vacuum Pump Exhaust Filter
Reference Materials
004-16843-00 Reference Material 13X Zeolite Micropore reference material
004-16844-00 Reference Material Y Zeolite Micropore reference material
004-16821-00 Reference Material Silica Alumina Reference material for surface area and pore volume, S(BET) appr. 200 m2/g
004-16833-00 Reference Material Carbon Black Reference material for surface area, S(BET) appr. 30 m2/g
004-16858-00 Reference Material Alumina Reference material for surface area, S(BET) appr. 5 m2/g
004-16816-00 Reference Material Alumina Reference material for surface area with Krypton analysis, S(BET) appr. 0.25 m2/g
General Operating Supplies
003-63801-01 Cable Ethernet Straight-Thru For connecting the instrument to a computer
202-25849-00 Dewar for Cold Trap 3 ltr
202-25850-00 Dewar for Analysis Port 3 ltr
202-31707-00 Cover Analysis Dewar
202-31708-00 Cover for Cold Trap Dewar
206-14701-00 Dewar Shield For use on sample port, cold trap, and degas ports
202-14702-00 Dewar shield  For use with Chiller Dewar Option
202-33053-00 Stainless Steel Dewar Kit 4 ltr, wide mouth, includes analysis dewar, cold trap dewar, and elevator adapter. Typically provides greater than 40 hours of unattended analysis.
240-25901-00 Dewar Dip Stick For checking liquid nitrogen level in Dewar
200-25840-00 Saturation Pressure (P0) Tube Includes isothermal jacket
004-25006-00 O-Ring for P0 Tube Size 006, Buna-N
003-26043-00 Heating Mantle With type K thermocouple, up to 450 °C, 24 V
003-26045-00 Heating Mantle  Side-laced to accommodate monolithic & nonstand sample tubes, with type K thermocouple, up to 450 °C, 24 V
230-25808-00 Heating mantle clip For monolithic & nonstandard sample tubes
004-61063-00 Tube for Cold Trap 1/2 in. OD stem
004-25469-00 O-ring for Cold Trap Size 014, Buna-N
200-25979-00 Nut for Cold Trap
Sample Tubes and Accessories
202-33100-06 Physisorption Operating Supplies Includes: 3 sample tubes (1/2 in.), O-rings, sample port frits, 1/8 Peek ferrule sets
202-33100-12 Extended Physisorption Operating Supplies Includes: 6 sample tubes (1/2 in.), 1 filler rod, 1 isothermal jacket, 3 sample tube stoppers, O-rings, sample port frits, 1/8 Peek ferrule sets, sample tube brush, dewar cover, reference material
240-61003-00 Sample Tube, 1/2 in.
240-61002-00 Sample Tube, 3/8 in.
240-61001-00 Sample Tube, 1/4 in.
202-25903-00 Isothermal Jacket for 1/2 in. Sample Tube
202-25902-00 Isothermal Jacket for 3/8 in. Sample Tube
202-25901-00 Isothermal Jacket for 1/4 in. Sample Tube
240-61016-00 Fillder Rod for 1/2 in. Sample Tube
240-61015-00 Filler Rod for 3/8 in. Sample Tube
240-61014-00 Filler Rod for 1/4 in. Sample Tube
240-32000-00 Stopper for 1/2 in. Sample Tube
004-32004-00 Stopper for 3/8 in. Sample Ttube
004-32604-00 Cap (stopper) for 1/4 in. Sample Tube 
260-25843-00 Ferrule for 1/2 in. Sample Tube
240-25802-00 Ferrule for 3/8 in. Sample Tube
240-25803-00 Ferrule for 1/4 in. Sample Tube
004-25044-00 O-Ring for 1/2 in. Sample Tube Size 013, Buna-N
004-25022-00 O-Ring for 3/8 in. Sample Tube Size 012, Buna-N, 
004-25466-00 O-Ring for 1/4 in. Sample Tube Size 010, Buna-N, 
260-25890-00 Seal Frit for 1/2 in. Sample Tube  With built-in check valve for air-sensitive samples
260-25891-00 Opener for Seal Frit Installed in ports to open Seal Frits
004-54130-00 Removal Tool for Seal Frit opener Tool to install and remove Seal Frit opener
004-54618-00 Tool for Removing the Sample Port O-Ring
004-27041-00 Sample Port Frit 20 µm, SS, 1/4 in.
004-25466-00 O-Ring for Sealing Frit in Sample Port Size 010, Buna-N
240-14855-00 Sample Tube Holder Rack for 12 sample tubes
240-32805-00 Support for Sample Tube Weighing Sample tube holder for balance
240-25853-00 Funnel For sample tubes (fits various sample tube sizes)
004-54609-00 Brush For cleaning sample tube, 330 mm long
300-25824-00 Nut for Sample Tube
202-33052-00 22 mm ID Sample Tube Kit Includes 5 sample tubes and accessories, see kit contents below
202-61022-00 Sample Tube, 22 mm ID, 25 mm OD
202-25904-00 Isothermal Jacket for 25 mm Sample Tube
202-61022-01 Filler Rod for 25 mm Sample Tube
004-32230-00 Stopper for 25 mm Sample Tube
202-25870-00 Ferrule for 25 mm Sample Tube
004-25609-02 O-Ring Size 022, Buna-N
202-25868-00 Sample Port Fitting for 25 mm Sample Tube
202-25869-00 Nut for 25 mm Sample Tube
202-25871-00 Degas Port Fitting for 25 mm Sample Tube
202-31709-00 Dewar Cover for 25 mm Sample Tube
Vapor Option Supplies
003-20656-02 Cable, M/M 15 Pin D 5 ft straight-thru For connecting the controller to the vapor source
003-20656-03 Cable, M/M 25 Pin D 5 ft straight-thru For connecting the controller to the manifold
004-25103-00 Ferrule, Front, Teflon, 1/4 in. For sealing the vapor stem assembly to the vapor connector
004-25104-00 Ferrule, Rear, Nylon, 1/4 in. For sealing the vapor stem assembly to the vapor connector
004-25031-00 O-Ring for Replacement on the Vapor Stem Assembly Size 110, Kalrez 
004-25465-00 O-Ring for Replacement on the Vapor Stem Assembly Size 010, Kalrez 
004-61004-00 Dewar Flask 350 mL
004-61630-00 Glass Vapor Tube
202-25878-00 Sample Port Insulator
202-33054-02 Sample Tube Conductor Kit Contains 2 sample tube conductors and 2 O-Rings
202-34150-02 Vapor Stem Assembly
Software and Manual
202-20828-00 ASAP 2020 Plus Physisorption software program
202-33027-00 MicroActive Software Package, interactive data analysis software
202-42800-00 ASAP 2020 Plus Operator Manual (includes binder and dividers)
Temperature Control Devices
205-33005-00 ISO Controller Micromeritics’ ISO Controller utilizes thermoelectric cooling based on the Peltier principle. The unit is designed to maintain a constant temperature between 0 °C and 80 °C when using CO2, N2, and other gases for adsorption analysis. The device rapidly cools and efficiently maintains temperature with minimal electrical current required. The sample area will accommodate up to 3 sample tubes. Heat removal is uniform and accurate when the unit is used with an appropriate liquid (ambient water or liquid antifreeze). The dewar section is placed on the instrument dewar elevator and then raised into position for analysis.
025-00202-00 Chiller Dewar A closed plumbing system that circulates fluid from a temperature controlled bath into a small Dewar filled with antifreeze in which the sample tubes are immersed.
025-26004-00 Recirculating Bath Temperature range from -28 °C to 200 °C, 115 V, 60 Hz. Refrigerated and heating circulator for temperature control of the Chiller Dewar. Note: Recommended for use with the Chiller Dewar Option 025-00202-00
025-33001-00 RTD Probe for Recirculating Bath Temperature Control Optional RTD mounted in the bath and connected to the controller on the recirculating bath for more accurate temperature control (for use with 025/26004/00).
021-00000-00 LN2 transfer system For easy filling of sample Dewars; includes 47 L Dewar, mobile platform, and pump with 100 cm discharge line