Part Number Description Notes
No result
003-26018-00  Heating Mantle for Vapor Generator Heating mantle to generate vapor in the flask.
004-16247-00 Snoop For gas flowmeter and gas leak checking
004-16836-00  Silver Oxide Reference Material Reference materials for Temperature-Programmed Reduction (TPR) Analysis
004-25129-00  Kalrez O-ring for Vapor Generator Flask Recommended when using corrosive gases or vapors
004-25465-00 -010 Kalrez O-ring for Delay or Cold Trap Port Recommended when using corrosive gases or vapors
004-25474-00 -013 Kalrez O-ring for Sample Tube Inlet Recommended when using corrosive gases or vapors
004-25549-00 1/8in x 1/4in Tube OD Brass Reducer Reducer fittings for regulators
004-25678-00 -009 Kalrez O-ring for Sample Tube Outlet Recommended when using corrosive gases or vapors
004-25912-00 1/16in (0.16 cm³) PEEK Front and Rear Ferrule Set
004-25913-00 1/8in (0.32 cm³) PEEK Front and Rear Ferrule Set
004-27052-00 1/4in Diameter x 1/16in Thick 10 Micron Stainless Steel Port Frit Sample tube filter frit
004-32004-00 Rubber Stopper for Sample Tube Inlet Sample tube stopper to limit sample exposure to air when sample tube is outside of the instrument
004-32164-01 4in x 6in Bag of Quartz Wool Recommended quartz wool with low emission of quartz particles
004-32187-00 Cotton Flannel Gloves for Handling Hot Components
004-32602-00 Septum for Injection Port Spare septum for the syringe injection port
004-32604-08 Plastic Cap for Sample Tube Outlet Sample tube cap to limit sample exposure to air when sample tube is outside of the instrument
004-33601-00 Gas Expansion Kit Expansion kit adds an additional outlet to regulators
004-54001-00 1/2in (1.27 cm³) x 9/16in (1.43 cm³) Open End Wrench
004-54006-00 5/16in (0.79 cm³) x 1/4in (0.64 cm³) Open End Wrench 
004-54010-00 3/8in (0.95 cm³) x 7/16in (1.11 cm³) Open End Wrench 
004-54113-00 7/64in Allen Ranch
004-54609-00 Wide Bristled Brush For cleaning sample tubes
004-54610-00 5/32in Nut driver for gas flowmeter
004-54805-00 Extraction Tool Facilitate the estraction of quartz wool from reactor
004-61064-00 600ml Dewar Used for the cold trap slurry. Dewar can also hold liquid nitrogen for BET analysis
004-61602-00 1ml Calibration Syringe For manual gas injections up to 1ml. Used when calibrating the loop volume or for manual calibration of reactive gases
004-61602-01 3 Replacement Injection Needles for 1ml Calibration Syringe Includes 3 spare needles
004-61604-00 10ml Calibration Syringe For manual gas injections up to 10ml. Used when calibrating the loop volume or for manual calibration of reactive gases
004-61604-01 3 Replacement Injection Needles for 10ml Calibration Syringe Includes 3 spare needles
004-62200-58  100 psig Gas Regulator with CGA 580 Fitting for N2, He, Ar, and Kr
004-62230-32 30 psig Gas Regulator with CGA 320 Fitting for CO2
004-62230-326 30 psig Gas Regulator with CGA 326 Fitting for N2O
004-62230-35 30 psig Gas Regulator with CGA 350 Fitting for CO and H2
004-62230-54 30 psig Gas Regulator with CGA 540 Fitting for O2
004-62230-58 30 psig Gas Regulator with CGA 580 Fitting for N2, He, Ar, and Kr
004-62230-59 30 psig Gas Regulator with CGA 590 Fitting for Air
004-62230-705 30 psig Gas Regulator with CGA 705 Fitting for NH3
008-42001-00 Analytical Methods in Fine Particle Technology A comprehensive resource of information on particle analysis. This hardbound text describes theory, instrumentation, and applications pertaining to chemisorption and temperature-programmed reactions, as well as other analytical methods used in the characterization of catalysts and other materials.
021-00000-00 Model 021 Liquid Nitrogen Transfer System For a safer and easy transfer of liquid nitrogen into smaller sample dewars. Includes 47-L Dewar, dolly, and pump with a 100-cm discharge line. Universal electrical input.
029-00000-00 CryoCooler II Provides seamless temperature control for fully automated temperature programmed reduction, desorption and reaction analysis. Allows furnace system to hold sample at approximately -120 °C.
029/33030/00 CryoCooler Mounting Hose Bracket The bracket helps to hold the CryoCooler hose onto the furnace without straining the tube on the furnace
201-25818-00 6ft Stainless Steel Gas Inlet Line Assembly Includes stainless steel tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end)
201-25818-01 16ft Stainless Steel Gas Inlet Line Assembly Includes stainless steel tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end)
230-31801-00 Half Cover for 600ml Cold Trap Dewar Two needed per 600ml dewar
240-25853-00 Sample Tube Funnel For loading samples into sample tube
248-32702-00 Quartz Filter Disk 100 pack of 11mm x 0.43mm 100% pure quartz microfiber filter sheets. For sample preparation, provides a flat bed.
280-32800-00 Foam Support for Weighing Sample Tube
290-25842-00 Gas Sampling Assembly Sampling compatible with calibration syringes
290-25845-00 Delay Line Assembly A delay path is used to reduce the perturbation (disturbance) of the gas flow caused by injections of
gas through the septum. Also used for BET Analysis
290-25846-00 6ft Copper Gas Inlet Line Assembly Includes copper tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end)
290-25846-01 16ft Copper Gas Inlet Line Assembly Includes copper tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end)
290-29800-00 10cm³ Bubble Burette 10cm3 Bubble Burette for measuring gas flow rates.
290-62600-00  0.5ml Injection Loop
290-62601-00 1ml Injection Loop
290-62602-00 5ml Injection Loop
291-33013-00 Vapor Generator Option to saturate the carrier gas with a vapor. Can be injected by the loop valve
291-33600-00 Extended Operation Supplies Includes reference material, O-rings, ferrules, dust mask, gloves, Dewar flask, thermocouple, sample tubes, frits, septum, and cold trap cover.
291-34005-00 KwikCool Provides rapid cooling of the furnace and decreases analysis time and increasing throughput. Works with compress air at room temperature
291-53801-00 Furnace Assembly
291-53904-00 Sample Thermocouple Shaped to enter the reactor measureing the sample temperature during the experiment
291-61702-00 Quartz Sample Tube U tube reactor 
291-61703-00  Thermocouple Quartz Sheath Sheath to protect thermocouple from incompatible gas
291-61704-00 50ml Flask for Vapor Generator Glass ade container for the liquid saturator
292-33001-00 AutoChem 2920 Operating Software and Operator's Manual
292-33015-01 Cirrus 2 200 AMU Mass Spectrometer Stand alone unit
292-33640-00 Cirrus 3 200 AMU Mass Spectrometer 200 AMU mass spectrometer connects directly to a dedicated port on the AutoChem II 2920 for detection and identification of low concentrations of condensable and/or reactive gases.
292-33640-CR Corrosion Resistence Cirrus 3 200 AMU Mass Spectrometer 200 AMU mass spectrometer connects directly to a dedicated port on the AutoChem II 2920 for detection and identification of low concentrations of condensable and/or reactive gases. Enhanced Chemical Resistant (ECR) Unit
292-34013-00 25.75 OHM FE-NI-AU Detector Assembly Complete TCD wired detector 25.75, ±0.75 Ohms @ 70 ±3 °F, with gold coated Fe-Ni filaments
292-42803-00 AutoChem 2920 Operator's Manual Printed manual with binder
292-46101-00 Cirrus Installation and Training for U.S.A. or Canada
292-46102-00 Cirrus Installation and Training for Europe
292-46103-00  Cirrus Installation and Training for Asia and All Other Countries
295-33021-00 KwikCool Vortex Supplies chilled cool air by a Vortex technique intended for rapid cooling of the furnace. It is not a temperature control device
930-54603-00 Narrow Bristled Brush For cleaning sample tubes
004/16825/00 Platinum Alumina Reference Material For Checking Pulse Chemisorption
292-32801-00 Protective Shelf Mat  
004/16848/00 Calcium Oxalate Monohydrate Reference Material For Check Temperature Programmed Desorption