Part Number Description Comments
No result
950-61701-00 Penetrometer Set, 15 cm3 Solid, 0.366 cm3 intrusion volume Includes 1 each penetrometer 920-61701-01 and closure set 950-25832-00
950-61702-00 Penetrometer Set, 15 cm3 Powder, 0.366 cm3 intrusion volume Includes 1 each penetrometer 920-61702-01 and closure set 950-25832-00
950-61703-00 Penetrometer Set, 15 cm3 Solid, 1.06 cm3 intrusion volume Includes 1 each penetrometer 920-61703-01 and closure set 950-25832-00
950-61704-00 Penetrometer Set, 15 cm3 Powder, 1.06 cm3 intrusion volume Includes 1 each penetrometer 920-61704-01 and closure set 950-25832-00
950-61705-00 Penetrometer Set, 15 cm3 Solid, 1.72 cm3 intrusion volume Includes 1 each penetrometer 920-61705-01 and closure set 950-25832-00
950-61706-00 Penetrometer Set, 15 cm3 Powder, 1.72 cm3 intrusion volume Includes 1 each penetrometer 920-61706-01 and closure set 950-25832-00
950-61707-00 Penetrometer Set, 5 cm3 Solid, 0.366 cm3 intrusion volume Includes 1 each penetrometer 920-61707-01 and closure set 950-25831-00
950-61708-00 Penetrometer Set, 5 cm3 Powder, 0.366 cm3 intrusion volume Includes 1 each penetrometer 920-61708-01 and closure set 950-25831-00
950-61709-00 Penetrometer Set, 5 cm3 Solid, 1.06 cm3 intrusion volume Includes 1 each penetrometer 920-61709-01 and closure set 950-25831-00
950-61710-00 Penetrometer Set, 5 cm3 Powder, 1.06 cm3 intrusion volume Includes 1 each penetrometer 920-61710-01 and closure set 950-25831-00
950-61711-00 Penetrometer Set, 5 cm3 Solid, 1.72 cm3 intrusion volume Includes 1 each penetrometer 920-61711-01 and closure set 950-25831-00
950-61712-00 Penetrometer Set, 5 cm3 Powder, 1.72 cm3 intrusion volume Includes 1 each penetrometer 920-61712-01 and closure set 950-25831-00
950-61713-00 Penetrometer Set, 3 cm3 Solid, 0.387 cm3 intrusion volume Includes 1 each penetrometer 920-61713-01 and closure set 950-25831-00
950-61714-00 Penetrometer Set, 3 cm3 Powder, 0.387 cm3 intrusion volume Includes 1 each penetrometer 920-61714-01 and closure set 950-25831-00
950-61715-00 Penetrometer Set, 3 cm3 Solid, 1.12 cm3 intrusion volume Includes 1 each penetrometer 920-61715-01 and closure set 950-25831-00
950-61716-00 Penetrometer Set, 3 cm3 Powder, 1.12 cm3 intrusion volume Includes 1 each penetrometer 920-61716-01 and closure set 950-25831-00
950-61720-00 Penetrometer Set, 3 cm3 Solid, 0.90 cm3 intrusion volume Includes 1 each penetrometer 920-61720-01 and closure set 950-25831-00
950-61724-00 Penetrometer Set, 15 cm3 Solid, 3.01 cm3 intrusion volume Includes 1 each penetrometer 920-61724-01 and closure set 950-25832-00
950-61725-00 Penetrometer Set, 15 cm3 Solid, 3.86 cm3 intrusion volume Includes 1 each penetrometer 920-61725-01 and closure set 950-25832-00
920-61701-01 Penetrometer, 15 cm3 Solid, 0.366 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61702-01 Penetrometer, 15 cm3 Powder, 0.366 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61703-01 Penetrometer, 15 cm3 Solid, 1.06 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61704-01 Penetrometer, 15 cm3 Powder, 1.06 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61705-01 Penetrometer, 15 cm3 Solid, 1.72 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61706-01 Penetrometer, 15 cm3 Powder, 1.72 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61707-01 Penetrometer, 5 cm3 Solid, 0.366 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61708-01 Penetrometer, 5 cm3 Powder, 0.366 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61709-01 Penetrometer, 5 cm3 Solid, 1.06 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61710-01 Penetrometer, 5 cm3 Powder, 1.06 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61711-01 Penetrometer, 5 cm3 Solid, 1.72 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61712-01 Penetrometer, 5 cm3 Powder, 1.72 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61713-01 Penetrometer, 3 cm3 Solid, 0.387 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61714-01 Penetrometer, 3 cm3 Powder, 0.387 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61715-01 Penetrometer, 3 cm3 Solid, 1.12 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61716-01 Penetrometer, 3 cm3 Powder, 1.12 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61720-01 Penetrometer, 3 cm3 Solid, 0.90 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25831-00
920-61724-01 Penetrometer, 15 cm3 Solid, 3.01 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
920-61725-01 Penetrometer, 15 cm3 Solid, 3.86 cm3 intrusion volume Penetrometer glassware only; use with closure set 950-25832-00
950-33605-00 Penetrometer Closure Kit for 3cm3 and 5 cm3 Penetrometers Includes six 3 cm3 and 5 cm3 penetrometer closure sets, 950-25831-00, and closure nut holder 950-09802-00 and seal wrench 950-09803-00
950-33606-00 Penetrometer Closure Kit for 15 cm3 Penetrometers Includes six 15 cm3 penetrometer closure sets, 950-25832-00, and closure nut holder 950-09802-00 and seal wrench 950-09803-00
950-25831-00 Closure Set for 3 cm3 and 5 cm3 Penetrometers Includes 1 each closure nut 950-25831-01 and closure nut 950-25831-01 for 3 cm3 and 5 cm3 penetrometers
950-25832-00 Closure Set for 15 cm3 Penetrometers Includes 1 each closure nut 950-25832-01 and closure nut 950-25832-01 for 15 cm3 penetrometers
950-25831-01 Closure Nut for 3 cm3 and 5 cm3 Penetrometers Penetrometer closure nut for all 3 cm3 and 5 cm3 penetrometers
950-25831-02 Closure Seal for 3 cm3 and 5 cm3 Penetrometers Penetrometer closure seal for all 3 cm3 and 5 cm3 penetrometers
950-25832-01 Closure Nut for 15 cm3 Penetrometers Penetrometer closure nut for all 15 cm3 penetrometers
950-25832-02 Closure Seal for 15 cm3 Penetrometers Penetrometer closure seal for all 15 cm3 penetrometers
950-09802-00 Penetrometer Closure Nut Holder Used to hold penetrometer closure nut while tightening before analysis, and while loosening after analysis
950-09803-00 Penetrometer Closure Seal Wrench Used to tighten penetrometer closure seal before analysis, and loosen seal after analysis
950-25831-03 Spacer for 3 cm3 and 5 cm3 Penetrometers Used to properly position penetrometer while in low pressure port so as to ensure connection to banana plug in capacitance detector assembly
942-25863-00 Spacer for 15 cm3 Penetrometers Used to properly position penetrometer while in low pressure port so as to ensure connection to banana plug in capacitance detector assembly
962-25807-00 Penetrometer Safety Enclosure Holds penetrometer securely in place while viewing penetrometer installed into low pressure port
950-25822-00 Penetrometer Weighing Support Holds penetrometer assembly while weighing
950-25820-00 Rack for Penetrometer Storage Securely holds empty penetrometers to help prevent breakage when not in use
962-25827-00 Rack for Filled Penetrometers Holds filled penetrometers upright so as to facilitate movement between instrument and balance when determining Assembly Mass
930-54601-00 Cleaning Brush for Penetrometer with 0.4 cm3 Stem Volume Used to clean inside 0.4 cm3 penetrometer stems
930-54602-00 Cleaning Brush for Penetrometer with 1.1 cm3 Stem Volume Used to clean inside 1.1 cm3 penetrometer stems
930-54603-00 Cleaning Brush for Penetrometer with 1.8 cm3, 3.3 cm3, and 4.2 cm3 Stem Volume Used to clean inside 1.8 cm3, 3.3 cm3, and 4.2 cm3 penetrometer stems
Routine Operating Supplies
004-16007-00 Apiezon Type H High Vacuum Grease Used to seal between penetrometer and closure nut
920-16001-00 High Pressure Fluid, 1 L Used to fill high pressure chamber during analysis; not used in the hydraulic pump
008-16045-00 Silicone High Vacuum Grease Used to lubricate low pressure seals; apply small amount to penetrometer stems or low pressure filler rods
004-16011-00 Hydraulic Pump Oil, Synthetic 15W-50 Grade Used in the hydraulic pump that generates pressure for the high pressure system; not used in the high pressure port
004-16004-01 Triple Distilled Mercury Ships as hazardous material; importation is limited by some countries.  Check with Micromeritics Representative for more details.
942-25823-00 Syringe, 50 mL For adding high pressure fluid to chamber, and for removing it from chamber
962-33601-00 Operating Supplies Includes one Liter of high pressure fluid 920-16001-00, two unmodified banana plugs 003-21273-00, four modified banana plugs 930-25849-00, valve spanner 004-54039-00, mercury vapor filter 962-27000-00, and package of 10 mercury vapor detection tubes
962-33602-00 Extended Operating Supplies Includes Apiezon vacuum grease 004-16007-00, two Liters of high pressure fluid 920-16001-00, four unmodified banana plugs 003-21273-00, ten modified banana plugs 930-25849-00, valve spanner 004-54039-00, three mercury vapor filters 962-27000-00, and package of 10 mercury vapor detection tubes 962-29601-00
Routine Maintenance Supplies
003-21273-00 Banana Plug for Capacitance Detector Assemblies, unmodified Replacement banana plugs for low pressure and high pressure capacitance detector assemblies
922-09808-00 Banana Plug Tool For removal and replacement of banana plugs for capacitance detector assemblies and high pressure feedthrough assemblies
920-33616-00 High Pressure Vessel Maintenance Kit Includes two each backup rings 004-25297-00, high pressure seals 922-25890-00, O-rings for vent valve 004-25034-00, and modified banana plugs 930-25849-00, as well as six penetrometer contacts 930-25817-00 and instruction sheet
922-33607-00 High Pressure Chamber Plug Seal Kit Includes two each backup rings 004-25297-00 and high pressure seals 922-25890-00, as well as instruction sheet
004-25297-00 Backup Ring for High Pressure Chamber Plug Seal Replacement high pressure chamber plug seal backup ring
922-25890-00 High Pressure Chamber Plug Seal Replacement high pressure chamber plug seal
004-25034-00 O-ring for High Pressure Chamber Vent Valve Replacement O-ring for vent valve located on top of the high pressure chamber
930-25817-00 Penetrometer contact for High Pressure Chamber Replacement penetrometer contact for high pressure chamber plug
930-25849-00 Banana Plug for High Pressure Feedthrough Assemblies, modified Replacement banana plugs for high pressure feedthrough assemblies in the bottom of the high pressure ports
962-33002-00 Mercury Reservoir Cap Assembly Replacement cap for mercury reservoir filling port
004-25652-00 O-ring for Mercury Reservoir Cap Replacement O-ring for mercury reservoir filling port
942-25600-00 Cover for Spilled Mercury Containment Dish Replacement cover for mercury spill containment dish
003-51123-00 6.25 Amp Fuse, 3AG Slo-Blo 250 VAC Replacement fuse for 100 to 120 volt installations
003-51134-01 5 Amp Fuse, 5x20 mm Slo-Blo 250 VAC CE Replacement fuse for 220 to 240 volt installations
003-63801-01 Ethernet Cable Replacement Ethernet cable for connection of AutoPore to controlling computer
004-54039-00 Spanner for Solenoid Valves Spanner to facilitate replacement of solenoid valve plungers
930-17801-00 Penetrometer Simulator, 82 pF Penetrometer simulator for use when verifying calibration of capacitance detector system, 82 pF
930-17801-01 Penetrometer Simulator, 150 pF Penetrometer simulator for use when verifying calibration of capacitance detector system, 150 pF
930-17801-05 Penetrometer Simulator, 15 pF Penetrometer simulator for use when verifying calibration of capacitance detector system, 15 pF
Reference Material and Reference Volume Capsules for Operational Verification
004-16822-00 Reference Material for Total Pore Volume and Median Pore Diameter Reference material for operational verification
940-34801-00 Mercury Reference Volume Kit Includes two small capsule assemblies 940-34800-00, 2 large capsule assemblies 940-34800-01, 25 replacement O-rings 004-25646-00, one package each of 8 µm membranes 940-25600-00 and 3 µm membranes 940-25600-01, storage case and instruction manual
940-34800-00 Small Mercury Reference Capsule Assembly Reference volume capsule assembly, nominal 0.24 mL capacity
940-34800-01 Large Mercury Reference Capsule Assembly Reference volume capsule assembly, nominal 0.80 mL capacity
940-14800-00 Reference Capsule Retaining Clip Replacement retaining clip for reference volume capsule assemblies
004-25646-00 Reference Capsule O-ring Replacement O-ring for reference volume capsule assemblies
940-25600-00 Reference Capsule 8 µm Member, Package of 100 Replacement 8 µm membrane for reference volume capsule assemblies
940-25600-01 Reference Capsule 3 µm Member, Package of 100 Replacement 3 µm membrane for reference volume capsule assemblies
Mercury Safety Accessories
090-00000-00 QuikVac Mercury Clean-up Accessory Mercury spill vacuum and containment accessory, capable of holding up to 250 mL of recovered mercury, with replaceable activated charcoal filter
942-33021-00 Exhaust Fan Kit Optional kit to pull fresh air across mercury reservoir and then exhaust it to rear of instrument; port on rear of instrument needs to be ducted properly to room ventilation system that is capable of handling mercury vapors
962-25859-00 Mercury Vapor Filter Assembly Replacement mercury vapor filter for vacuum pump exhaust
962-29600-00 Mercury Vapor Detection Pump Replacement mercury vapor detection pump for testing environment for mercury vapors using disposable mercury vapor detection tubes
962-29601-00 Mercury Vapor Detection Tube, Package of 10 Replacement mercury vapor detection tubes for use with mercury vapor detection pump
004-32031-00 Low Pressure Mercury Drip Tray Replacement low pressure mercury drip tray
Low Pressure Vacuum System Replacement Items and Supplies
062-62801-11 Vacuum Pump, 100 to 120 VAC Replacement vacuum pump for evacuation of low pressure system, for 100 to 120 VAC installations
062-25801-23 Vacuum Pump, 220 to 240 VAC Replacement vacuum pump for evacuation of low pressure system, for 220 to 240 VAC installations
004-27040-00 Vacuum Pump Exhaust Filter Replacement exhaust filter for low pressure vacuum pump
004-16003-01 Vacuum Pump Oil, 1L Vacuum oil for low pressure vacuum pump
004-25630-00 Centering Ring NW 16 Replacement centering ring for connection to vacuum pump exhaust port
004-25509-00 Clamp NW 10/16 Replacement clamp for connection to vacuum pump exhaust port
Gas Supply Accessories
004-62200-58 Gas Regulator, 2-stage 100 psig outlet, CGA 580 gas cylinder fitting Regulator for compressed gas supply to low pressure system
230-02001-00 Gas Inlet Line, 1/8 inch OD x 6 feet L Gas inlet line for compressed gas supply to low pressure system
004-25549-00 Reducing Union, 1/4 inch to 1/8 inch Reducing union to connect gas inlet line 230-02001-00 to gas regulator 004-62200-58
004-33601-00 Two-outlet Expansion Kit for Gas Regulator Expansion kit to allow use of one gas cylinder for multiple instruments
004-33602-00 Pressure Relief Kit for Gas Regulator Used to prevent over-pressurization of gas regulator outlet
Software and Operator's Manual
962-20800-00 AutoPore V Software Latest version of AutoPore V operating software
962-42800-00 AutoPore V Operator's Manual Printed AutoPore Operator's Manual, with binder