004-62230-58 Gas Regulator, CGA 580   30 psig; Compatible with Ar, He, Kr, and N2
004-62230-32 Gas Regulator, CGA 320  30 psig; Compatible with CO2
004-33601-00 Expansion Kit Adds additional outlet to gas regulator. Includes fittings and instructions
004-33602-00 Pressure Relief Kit Prevents excessive gas pressure in event of regulator failure. Not to be used with noxious gas. 
004-25549-00 Gas Line Reducer 1/8 in. (0.32 cm) x 1/4 (0.64 cm) in. tube for gas lines
201-25818-01 Stainless Steel Gas Inlet Line 5m (16 ft.)
290-25846-01 Copper Gas Inlet Line 5m (16 ft.)
290-25846-00 Copper Gas Inlet Line 6 ft. 
062-00000-11 110/120V Vaccum Pump with built-in anti-suckback valve; Includes vacuum hose, fittings, exhaust filter, oil and manual
062-00000-23 220/240V Vaccum Pump with built-in anti-suckback valve; Includes vacuum hose, fittings, exhaust filter, oil and manual
062-00004-00 Hybrid Turbo Vacuum Pump assembly for Krypton units only
004-16003-01 Vacuum Pump Oil 1 Liter; for vacuum pump
004-27040-00 Exhaust Filter For vacuum pump exhaust
062-33002-00 Oil Vapor Trap For vacuum pump
004-16830-00 Activated Alumina Pellets 500g; for oil vapor trap
021-00000-00 Liquid Nitrogen Transfer System  Model 021 LN2 transfer system, for easy filling of sample Dewars; includes 47-L dewar, mobile platform, and pump with 100-cm discharge line
303-25825-00 Glass Dewar 2.75 Liters
004-34891-00 Stainless Steel Dewar 4.0 Liters
240-25901-00 Dip Stick  for checking liquid nitrogen level in Dewar
300-31802-02 Dewar Cover  for 3/8-in. Tube; used during analysis to lenghten the lifetime of a dewar
300-31802-03 Dewar Cover  for 1/2-in. Tube; used during analysis to lenghten the lifetime of a dewar
240-25895-00 Dewar Insulator  used when dewar is not in use
025-00303-00 Chiller Dewar Micromeritics’ Chiller Dewar is a closed loop recirculating system that utilizes a high surface area copper coil to provide excellent heat transfer between the dewar and the recirculating liquids. Temperature control is provided through Fan external recirculating bath or chiller bath which are supplied as accessory items. The Chiller Dewar is easily mounted to the system’s elevator using the supplied clamping screw and bar set. The unit comes complete with all necessary fittings and tubing for connection to the recirculating bath. An external RTD is also provided which mounts inside the dewar. The RTD connects to the recirculating bath and ensures that precise temperature control is maintained over the course of the experiment
205-33005-00 Iso Controller  Micromeritics’ ISO Controller utilizes thermoelectric cooling based on the Peltier principle. The unit is designed to maintain a constant temperature between 0 °C and 80 °C when using CO2, N2, and other gases for adsorption analysis. The device rapidly cools and efficiently maintains temperature with minimal electrical current required. The sample area will accommodate up to 3 sample tubes. Heat removal is uniform and accurate when the unit is used with an appropriate liquid (ambient water or liquid antifreeze). The dewar section is placed on the instrument dewar elevator and then raised into position for analysis.
302-61001-00 1/4 in. OD Tristar Sample Tube for analyzing powdered samples where free space management (with a filler rod inserted) is critical
302-61001-01 3/8 in. OD Tristar Sample Tube for analyzing any type of sample
302-61001-02 1/2 in. OD Tristar Sample Tube for analyzing larger pieces of granular or pelleted samples
302-61002-00 1/4 in OD Flat Bottom Sample Tube
302-61002-01 3/8 in OD Flat Bottom Sample Tube
302-61002-02 1/2 in OD Flat Bottom Sample Tube
302-33602-00 3/8 in. Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
302-33603-00 1/2 in. Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
302-33601-00 1/4 in. Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
302-33604-00 1/4 in. Flat Bottom Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cove
302-33605-00 3/8 in. Flat Bottom Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cove
302-33606-00 1/2 in. Flat Bottom Sample Tube Kit includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cove
004-32004-00 Rubber Stopper for Sample Tube For 1/2 in. and 3/8 in sample tubes
004-32604-08 Plastic Cap for Sample Tube For 1/4 in. sample tubes
240-25853-00 Sample Tube Funnel For filling sample tubes
300-25825-00 Sample Tube Ferrule For 1/4 in. sample tube
300-25826-00 Sample Tube Ferrule For 3/8 in. sample tube
260-25843-00 Sample Tube Ferrule For 1/2 in. sample tube
240-14855-00 Sample Tube Rack  For supporting sample tubes
300-32800-00 Weighing Support For supporting samples while weighing
004-25466-00 Duro Buna-N O-Ring Size 10 for 1.4-in. (0.64-cm) sample tube
004-25022-00 Duro Buna-N O-Ring Size 12 for 3/8 in. (0.96-cm) OD sample tube
004-25469-00 Duro Buna-N O-Ring Size 14 for 1/2-in. (1.27-cm) OD sample tube
302-25822-00 1/4 in. Isothermal Jacket 
302-25822-01 3/8 in. Isothermal Jacket 
302-25822-02 1/2 in.Isothermal Jacket
302-25821-00 1/4 in. Hanging Filler Rod
302-25821-02 1/2 in. Hanging Filler Rod
302-25821-01 3/8 in. Hanging Filler Rod
004-54609-00 Brush, Tube Cleaning For cleaning 1/2 in. sample tubes
004-54104-00 Brush, Tube Cleaning For cleaning 3/8-in. sample tubes
004-16821-00 Silican-Alumina Reference Material SA, approximately 198 m²/g
004-16833-00 Carbon Black Reference Material SA, approximately 24.1 m²/g
004-16816-00 Alumina Reference Material SA, approximately 0.25 m²/g; for krypton analysis
004-16858-00 Alumina Reference Material  SA, approximately 5.2 m²/g
003-22617-00 Solenoid Manifold Valve with 0.025 Orifice for valves 1 through 10
003-22626-00 Solenoid Manifold Valve with 0.060 Orifice for valves 11 through 13
004-27046-00 40 micron Sample Port Frit
004-54618-00 Sample Port O-ring Removal Tool  removes sample port O-ring. 
260-25873-00 Sample Port Plug 12mm dia x 25 mm; glass shell vial
004-25630-00 Centering Ring, NW 16 Standard 
004-25491-02 Centering Ring, NW 40 Buna-N, AL for Pump, Vacuum, Hybrid Turbo
302-33607-00 Seal Frit Kit includes three seal frits, nine openers, three filler rods, installation tool and instructions.
302-33600-00 Operating Supplies with 3/8 in. Tubes
302-33608-00 Krypton Upgrade Kit
008-42001-00 Analytical Methods in Fine Particle Technology by:  Paul A. Webb and Dr. Clyde Orr This book has been prepared to serve those just entering this field of technology as well as experienced researchers seeking insight into particular problems and guidance in achieving the utmost from their testing and research.
200-42901-00 Gas Adsorption Theory Poster 24'' X  36''
200-42902-00 Gas Adsorption Apparatus Poster 24'' X  36''
202-33027-00 MicroActive Interactive Data Analysis Software V5.02 Micromeritics’ innovative MicroActive software allows users to interactively evaluate isotherm data from Micromeritics ASAP, TriStar, and Gemini gas adsorption instruments. Users can easily include or exclude data, fitting the desired range of experimentally acquired data points using interactive, movable calculation bars. Isotherms can be viewed on either a linear or logarithmic scale and available to the user under each calculation model. No need to generate reports to review results – now see it graphically and interactively on screen.
003-63801-00 Ethernet Cable 
067-00000-00 Smart VacPrep without Vacuum Pump Smart VacPrep is an advanced six-port system that utilizes vacuum to prepare samples by heating and evacuation. Each of the ports may be operated independently. Samples may be added or removed from degas ports without disturbing the treatment of other samples undergoing preparation. Degassing automatically terminates when the samples have completed all programmed steps.
067-00000-11 Smart VacPrep with 110V Vacuum Pump
067-00000-22 Smart VacPrep with 230V Vacuum Pump
067-00001-00 Smart VacPrep with High-Vacuum 
061-00023-00 VacPrep 061 Degasses up to six samples at up to 400°C with either flowing gas or evacuation (evacuation requires a vacuum pump and gas regulator).
060-00023-00 FlowPrep 060 Degasses up to six samples at up to 400°C  with flowing gas (requires a gas regulator)