Home   >  

Accessories


TriStar II Series

Cap and Stopper

Part No. 004-32604-08
Cap for 1/4 in. sample tube
Qty:
Part No. 004-32004-00
Stopper, For 1/2 in. and 3/8 in sample tubes
Qty:

Weighing Support

Part No. 300-32800-00
For supporting samples while weighing
Qty:

Dewar

Part No. 004-34891-00
Stainless steel Dewar, 4.0 liters
Qty:
Part No. 240-25901-00
Dip stick; for checking liquid nitrogen level in Dewar
Qty:
Part No. 300-25861-20
G;ass Dewar. 2.75 Liters - TriStar II
Qty:

Oil

Part No. 004-16003-01
1 Liter, for vacuum pump
Qty:

Oil Vapor Trap

Part No. 062-33002-00
For vacuum pump
Qty:

Kit(s)

Part No. 302-33600-00
Operating Supplies for the TriStar II, 3/8 in.
Qty:
Part No. 302-33607-00
TriStar II and TriStar II PLUS
Seal Frit Kit; includes three seal frits, nine openers, three filler rods, installation tool and instructions.
Qty:
Part No. 302-33608-00
Upgrade Kit, Krypton, TriStar II
Qty:

VacPrep 061

Part No. 061-00030-00
Degasses up to six samples at up to 400 °C with either flowing gas or evacuation (evacuation requires a vacuum pump and gas regulator).
Qty:

Filler Rods for TriStar II and TriStar II PLUS

 

 

Part No. 302-25821-00
Assy. Hanging Filler Rod, 1/4 inch Sample tube
Qty:
Part No. 302-25821-01
Assy, Hanging Filler Rod, 3/8 Sample Tube
Qty:
Part No. 302-25821-02
Assy, Hanging Filler Rod, 1/2 inch
Qty:

Tool, for removing sample port O-ring

Part No. 004-54618-00
Qty:

Plastic Cap for 1/4 sample tube

Part No. 004-32604-08
CAP, PLASTIC, .225Dx5/16,VINYL
Qty:

Liquid Nitrogen Transfer System

Part No. 021-00000-00
Model 021 LN2 transfer system, for easy filling of sample Dewars; includes 47-L dewar, mobile platform, and pump with 100-cm discharge line
Qty:

Sample Tube Funnel

Part No. 240-25853-00
For filling sample tubes
Qty:

O-Ring

Part No. 004-25022-00
Buna-N, 012, for 3/8 in. (0.96-cm) OD sample tube
Qty:
Part No. 004-25469-00
Buna-N, 014, for 1/2-in. (1.27-cm) OD sample tube
Qty:
Part No. 004-25466-00
Buna-N, 010, for 1.4-in. (0.64-cm) sample tube
Qty:

Insulating Dewar Cover

Part No. 300-31802-03
For 1/2-in. OD sample tube
Qty:
Part No. 300-31802-02
For 1/4-in. and 3/8-in. OD sample tube
Qty:

Filter

Part No. 004-27040-00
For vacuum pump exhaust
Qty:

Activated Alumina Pellets

Part No. 004-16830-00
500 grams, for oil vapor trap
Qty:

Analytical Methods in Fine Particle Technology

This book has been prepared to serve those just entering this field of technology as well as experienced researchers seeking insight into particular problems and guidance in achieving the utmost from their testing and research.
Part No. 008-42001-00
Analytical Methods in Fine Particle Technology
by:  Paul A. Webb and Dr. Clyde Orr
Qty:

FlowPrep 060

Part No. 060-00030-00
Degasses up to six samples at up to 400 oC with flowing gas (requires a gas regulator)
Qty:

Gas Inlet Line Assembly

Part No. 290-25846-01
Gas Inlet line, Copper, 5m (16 ft.)
Qty:
Part No. 290-25846-00
Gas inlet line assembly, Copper, 6 ft.
Qty:
Part No. 201-25818-01
Gas Inlet Line, Stainless Steel, 5m (16 ft.)
Qty:

Centering Ring

Ring Centering, NW 16 - standard
Part No. 004-25491-02
Ring, Centering, NW 40, Buna-N, AL for Pump, Vacuum, Hybrid Turbo
Qty:
Part No. 004-25630-00
Qty:

Smart VacPrep

Smart VacPrep is an advanced six-port system that utilizes vacuum to prepare samples by heating and evacuation. Each of the ports may be operated independently. Samples may be added or removed from degas ports without disturbing the treatment of other samples undergoing preparation. Degassing automatically terminates when the samples have completed all programmed steps.

Link to Product page

Part No. 067-00000-00
Smart VacPrep without vacuum pump
Qty:
Part No. 067-00000-22
230 volt
Qty:
Part No. 067-00000-11
110 volt
Qty:
Part No. 067-00001-00
with high-vacuum
Qty:

Vacuum Pump

Part No. 062-00000-23
Vacuum pump with built-in anti-suckback valve, 220/240 VAC, includes hose kit
Qty:
Part No. 062-00004-00
Hybrid turbo vacuum pump assembly for Krypton units only
Qty:
Part No. 062-00000-11
Vacuum pump with built-in anti-suckback valve, 110/120 VAC, includes hose kit
Qty:

Sample Tube Rack

Part No. 240-14855-00
For supporting sample tubes
Qty:

Reference Material

Part No. 004-16816-00
Reference Material, Alumina, ~ 0.25 m2 /g, 15 g; for krypton analysis
Qty:
Part No. 004-16818-00
Reference Material, Glass, ~ 5.8 m2/g, 10 g
Qty:
Part No. 004-16833-00
Carbon Black, 24.1 m²/g
Qty:
Part No. 004-16821-00
Silica-alumina pellets, surface area approx. 198 m²/g, 10 g
Qty:

Manifold Valves

Part No. 003-22626-00
Solenoid with 0.060 Orifice, for valves 11 through 13
Qty:
Part No. 003-22617-00
Solenoid with 0.025 orifice, for valves 1 through 10
Qty:

Reducer

Part No. 004-25549-00
1/8 in. (0.32 cm) x 1/4 (0.64 cm) in. tube for gas lines
Qty:

Software and Manuals

Part No. 065-42801-00
Operator's manual, SmartPrep 065
Qty:
Part No. 302-42828-01
TriStar II Operators manual
Qty:
Part No. 302-33011-00
Software Pkg. TriStar II 3020 CFR, (software and manual)
Qty:
Part No. 303-42800-00
TriStar II Plus - operator’s manual
Qty:
Part No. 302-33002-00
Software Pkg, TriStar II 3020, (software and manual)
Qty:
Part No. 303-20800-00
TriStar II Plus- current version software
Qty:
Part No. 065-33001-00
Software package allows direct operation of the SmartPrep
Qty:
Part No. 302-20828-00
TriStar II - current version software
Qty:

Gas Adsorption Apparatus Poster

Part No. 200-42902-00
24" x 36"
Qty:

Isothermal Jackets for TriStar II and TriStar II PLUS

 

 

Part No. 302-25822-01
Isothermal Jacket 3/8 in.
Qty:
Part No. 302-25822-02
Isothermal Jacket 1/2 in.
Qty:
Part No. 302-25822-00
Isothermal Jacket 1/4 in.
Qty:

MicroActive Interactive Software

Micromeritics’ innovative MicroActive software allows users to interactively evaluate isotherm data from Micromeritics ASAP, TriStar, and Gemini gas adsorption instruments. Users can easily include or exclude data, fitting the desired range of experimentally acquired data points using interactive, movable calculation bars. Isotherms can be viewed on either a linear or logarithmic scale and available to the user under each calculation model. No need to generate reports to review results – now see it graphically and interactively on screen.

Link to MicroActive webpage

 

Part No. 202-33027-00
MicroActive; includes software and operator’s manual. This program allows you to generate and manipulate data on a computer other than the one controlling the analyzer or to compare data from another instrument
Qty:

Plug, Sample Port (MS)

Part No. 260-25873-00
Qty:

Iso Controller Sub-Ambient, Thermoelectric Cooled Dewar

Micromeritics’ ISO Controller utilizes thermoelectric cooling based on the Peltier principle. The unit is designed to maintain a constant temperature between 0 °C and 80 °C when using CO2, N2, and other gases for adsorption analysis. The device rapidly cools and efficiently maintains temperature with minimal electrical current required. The sample area will accommodate up to 3 sample tubes. Heat removal is uniform and accurate when the unit is used with an appropriate liquid (ambient water or liquid antifreeze). The dewar section is placed on the instrument dewar elevator and then raised into position for analysis.
Part No. 350-33005-00
For TriStar II Plus
Qty:

Gas Regulator

Part No. 004-33601-00
Expansion Kit; adds additional outlet to gas regulator, includes fittings and instructions.
Qty:
Part No. 004-33602-00
Pressure Relief Kit; prevents excessive gas pressure in event of regulator failure. Not to be used with noxious gases.
Qty:
Part No. 004-62230-32
CGA 320, 320, 30 psig (Carbon Dioxide)
Qty:
Part No. 004-62230-58
CGA 580 fitting, 30 psig (Ar, He, Kr, N2)
Qty:

Sample Tube Ferrule

Part No. 300-25825-00
For 1/4 in. sample tube
Qty:
Part No. 300-25826-00
For 3/8 in. sample tube
Qty:
Part No. 260-25843-00
For 1/2 in. sample tube
Qty:

Brush

Part No. 004-54104-00
For cleaning 3/8-in. sample tubes
Qty:
Part No. 004-54609-00
For cleaning 1/2 in. sample tubes
Qty:

Dewar Depth Gauge

Part No. 240-25901-00
For determining depth of liquid nitrogen
Qty:

Port Frit

Part No. 004-27046-00
40 micron, for sample tube port
Qty:

Cable

Part No. 003-63801-00
Cable, Ethernet straight-thru
Qty:

Gas Adsorption Theory Poster

Part No. 200-42901-00
24" x 36"
Qty:

Sample Tubes for TriStar II and TriStar II PLUS

 

 

Part No. 302-61001-02
TriStar II and TriStar II PLUS
Sample Tube, 1/2 in. stem OD; for analyzing larger pieces of granular or pelleted samples
Qty:
Part No. 302-33602-00
Sample Tube Kit, 3/8 in; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-33605-00
Sample Tube Kit, 3/8 in, FLAT BOTTOM; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-61002-00
TriStar II and TriStar II PLUS
Sample tube 1/4 in. Stem OD, Flat Bottom

Qty:
Part No. 302-33603-00
Sample Tube Kit, 1/2 in; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-33606-00
Sample Tube Kit, 1/2 in, FLAT BOTTOM; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-61001-01
TriStar II Series
Sample Tube, 3/8 in. stem OD; for analyzing any type of sample
Qty:
Part No. 302-61002-02
TriStar II and TriStar II PLUS
Sample tube 1/2 in. Stem OD, Flat Bottom

Qty:
Part No. 302-33604-00
Sample Tube Kit, 1/4 in FLAT BOTTOM; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-61001-00
TriStar II and TriStar II PLUS
Series Sample Tube, 1/4 in. stem OD; for analyzing powdered samples where free space management (with a filler rod inserted) is critical
Qty:
Part No. 302-61002-01
TriStar II and TriStar II PLUS
Sample tube 3/8 in. Stem OD, Flat Bottom

Qty:
Part No. 302-33601-00
Sample Tube Kit, 1/4 in; includes six each sample tubes, O-rings and stoppers; three each isothermal jackets, filler rods, and ferrules; one sample tube brush; and a Dewar cover
Qty:
Part No. 302-61005-02
TriStar II and TriStar II PLUS
Filler Rod, for 1/2 in. sample tube when using the Seal Frit
Qty:

Seal Frit Kit

Seal Frit Kit; includes three seal frits, nine openers, three filler rods, installation tool and instructions
Part No. 302-33607-00
Qty:

Open Dewar Insulator

Part No. 240-25895-00
Qty:

Chiller Dewar

Micromeritics’ Chiller Dewar is a closed loop recirculating system that utilizes a high surface area copper coil to provide excellent heat transfer between the dewar and the recirculating liquids. Temperature control is provided through Fan external recirculating bath or chiller bath which are supplied as accessory items.

The Chiller Dewar is easily mounted to the system’s elevator using the supplied clamping screw and bar set. The unit comes complete with all necessary fittings and tubing for connection to the recirculating bath. An external RTD is also provided which mounts inside the dewar. The RTD connects to the recirculating bath and ensures that precise temperature control is maintained over the course of the experiment

Part No. 025-00303-00
For TriStar II 3020 and TriStar II PLUS
Qty:

Email Subscriptions

Sign Up Here



Information Security

Privacy Policy